Our highly skilled technicians are trained to effectively diagnose various engine complications, including fuel system blockages, electrical malfunctions, and cooling system failures, which can greatly impact a boat's operation. Utilizing advanced diagnostic tools and high-quality replacement parts, Mobile Marine can efficiently restore engines to their proper working condition, ensuring they run smoothly and reliably. We specialize in marine gasoline and diesel propulsion systems, including engine maintenance and repairs.

Mobile Marine believes that adhering to manufacturer specifications during repairs is crucial to maintaining warranty coverage, ensuring safety on the water, and preventing potential hazards. We recommend keeping a well-organized schedule of routine inspections and addressing repairs promptly. This will significantly help boat owners enjoy a more reliable and trouble-free boating experience, allowing them to fully appreciate their time on the water

Marine Engine Maintenance

Regular maintenance of marine engines is essential for optimal performance, longevity, and safety. Below are key components and practices to ensure your marine engine remains in excellent condition:

1. Routine Inspections

Conduct regular visual inspections of the engine compartment for signs of leaks, corrosion, or wear. Pay attention to hoses, connections, and mounting bolts.

2. Oil Changes

Replace the engine oil according to the manufacturer’s recommended schedule, typically every 100 hours of operation or at least annually. Use marine-grade oil to ensure better protection against corrosion and wear.

3. Coolant System Maintenance

Check coolant levels and condition regularly, replacing as necessary. Monitor hoses for cracks and leaks and consider flushing the coolant system every couple of years to prevent build-up and corrosion.

4. Fuel System Care

Inspect fuel filters and change them as recommended. Keep the fuel system clean and free from water and contaminants. Consider adding fuel stabilizers to prevent fuel degradation during long periods of inactivity.

5. Battery Maintenance

Check battery levels and terminals for corrosion. Clean and tighten connections, and ensure the battery holds a proper charge. Consider using a battery maintainer when the vessel is not in use.

6. Air Filter Inspection

Inspect and clean or replace air filters/spark arrestor as needed. A clean spark arrestor / air filter ensures optimal airflow to the engine, enhancing performance and fuel efficiency.

7. Propeller and Shaft Maintenance

Examine the propeller for dings or deformities and repair or replace as needed. Ensure the shaft is properly aligned and lubricated to prevent wear.

8. Drive Belts and Timing Components

Inspect drive belts for cracks and wear. Ensure proper tension and alignment, replacing them if signs of damage are evident. Check timing components periodically based on the manufacturer's guidelines.

9. Electrical System Checks

Regularly inspect wiring, fuses, and connections. Look for any signs of fraying or corrosion that can lead to electrical failures during operation.

10. Professional Service

Consider scheduling a professional maintenance service annually. A certified marine mechanic can perform in-depth inspections and maintenance, ensuring every aspect of the engine is addressed.

By adhering to these maintenance practices, you can significantly extend the life of your marine engine while ensuring its reliability and efficiency. Regular care not only protects your investment but also promotes safe boating experiences.

Marine Generator Maintenance and Repair

Regular maintenance of your generator is crucial to ensure its reliability, especially in a state like Maine where fluctuating weather conditions can demand dependable power sources. Here are key considerations for maintaining your generator:

1. Routine Inspections

  • Schedule Semi-Annual Inspections: Conduct thorough checks before and after the peak usage seasons, typically before winter and summer.

  • Visual Check: Inspect the unit for any signs of wear, rust, or damage.

2. Oil and Filter Changes

  • Change Oil Regularly: Follow manufacturer recommendations, usually every 100-150 hours of operation.

  • Replace Oil Filter: This should be done during every oil change to ensure the system remains clean and efficient.

3. Fuel System Maintenance

  • Inspect Fuel Lines: Look for cracks or leaks that could indicate wear or degradation.

  • Fuel Stabilizers: Use fuel stabilizers if the generator will not be used for extended periods to prevent fuel degradation.

4. Battery Care

  • Check Battery Charge: Ensure the battery is charged and terminals are clean and tight.

  • Replace as Needed: Batteries typically have a lifespan of 3-5 years, so plan for replacements accordingly.

5. Cooling System Checks

  • Inspect Cooling System: Make sure the coolant levels are adequate and there are no leaks.

  • Flush Cooling System: Regularly flush and replace the coolant to prevent overheating and prolong engine life.

6. Air Filter Maintenance

  • Replace Air Filters: A clogged air filter can affect performance; consider changing it every 100 hours of operation.

  • Clean Dust and Debris: Regularly remove any buildup around the generator to maintain airflow.

7. Run the Generator

  • Regular Testing: Run your generator at least once a month for about 30 minutes under a load to ensure it operates correctly.

  • Listen for Unusual Noises: Pay attention to any irregular sounds that might indicate issues requiring further investigation.

8. Professional Servicing

  • Engage a Qualified Technician: Have a professional technician perform comprehensive servicing at least once a year to assess crucial components and systems.

By adhering to these maintenance tips, you can ensure that your generator remains in top condition, ready to meet your power needs throughout the unpredictable Maine weather. Regular upkeep will not only extend the life of your generator but also enhance its performance reliability, offering peace of mind when you need it most.Proper maintenance and timely repair of your marine generator are crucial for ensuring reliability and longevity during marine operations. Here are key practices to consider:

Routine Maintenance

  1. Regular Inspections:

    • Conduct thorough inspections at regular intervals. Check for any signs of leaks, rust, or wear on components.

    • Verify that the generator mounting is secure and that there are no loose connections.

  2. Oil Changes:

    • Change the engine oil and oil filter based on the manufacturer’s recommendations or at least every9. Documentation

Keep a record of the tune-up, including the date and details of services performed. This information is valuable for future maintenance and can enhance resale value.

Regular tune-ups not only improve the efficiency and reliability of your generator but also enhance safety and reduce the risk of unexpected breakdowns. Schedule your generator tune-up annually or after a prolonged period of inactivity for the best results.

  1. Oil Changes: Change the engine oil and oil filter at the manufacturer-recommended intervals to ensure proper lubrication and engine health.

  2. Air Filter Inspection: Regularly inspect and clean or replace the air filter to prevent contaminants from entering the engine, which can cause performance issues.

  3. Fuel System Maintenance: Keep the fuel system clean by using fuel stabilizers, checking for leaks, and replacing fuel filters as specified in the owner's manual.

  4. Battery Care: Inspect the battery connections for corrosion and ensure the battery is charged. Clean the terminals and test the battery’s voltage regularly.

  5. Cooling System Checks: Ensure the cooling system is functioning correctly by inspecting hoses for wear and cracks, checking coolant levels, and replacing any damaged components.

  6. Electrical System Inspection: Examine all wiring and connections for signs of wear or corrosion. Ensure that fuses and circuit breakers are in good working order.

  7. Load Testing: Periodically perform a load test to assess the generator's capacity and ensure it can handle the electrical load placed on it during operation.

Repair Guidelines

  1. Identification of Issues: When faced with generator issues, start by identifying symptoms such as unusual noises, failure to start, or irregular power output.

  2. Troubleshooting: Use the manufacturer's troubleshooting guide to narrow down the problem. Check fuel supply, battery voltage, and electrical connections.

  3. Professional Assistance: For complex issues or repairs, seek professional assistance. Experienced technicians can diagnose and rectify problems that may not be apparent.

  4. Parts Replacement: Always use manufacturer-approved parts for replacements to maintain warranty and ensure compatibility with your generator.

  5. Documentation: Keep a record of all maintenance and repairs performed. This documentation can help in diagnosing future problems and is valuable if warranty assistance is needed.

  6. Safety Precautions: Always prioritize safety. Ensure the generator is turned off and properly disconnected from power sources before performing any maintenance or repairs.

Incorporating these maintenance practices and being proactive with repairs can greatly enhance the efficiency and reliability of your generator, ultimately providing peace of mind and ensuring readiness when you need it most.